Mar 11, 2025

Public workspaceOpen Field & Cylinder test Behavior Assays 

  • 1Allen Institute;
  • 2Zuckerman Mind Brain Behavior Institute, Columbia University;
  • 3Aligning Science Across Parkinson’s (ASAP) Collaborative Research Network
Icon indicating open access to content
QR code linking to this content
Protocol CitationAkira Fushiki 2025. Open Field & Cylinder test Behavior Assays . protocols.io https://dx.doi.org/10.17504/protocols.io.eq2ly6ypegx9/v1
Manuscript citation:
A Vulnerable Subtype of Dopaminergic Neurons Drives Early Motor Deficits in Parkinson’s Disease
Akira Fushiki, David Ng, Zachary R. Lewis, Archana Yadav, Tatiana Saraiva, Luke A. Hammond, Christoph Wirblich, Bosiljka Tasic, Vilas Menon, Joaquim Alves da Silva, Rui M. Costa
bioRxiv 2024.12.20.629776; doi: https://doi.org/10.1101/2024.12.20.629776
License: This is an open access protocol distributed under the terms of the Creative Commons Attribution License,  which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Protocol status: Working
We use this protocol and it's working
Created: February 19, 2025
Last Modified: March 11, 2025
Protocol Integer ID: 122195
Keywords: ASAPCRN
Funders Acknowledgements:
Aligning Science Across Parkinson’s
Grant ID: ASAP-020551
Abstract
Protocols for mouse behavioral studies using the open field test and the cylinder test from Fushiki et al 2024.
Guidelines
The habituation period is used in this protocol and is recommended especially for assessing basic locomotor activity or movement, but it depends on the experiment. Longer acclimation periods can reduce exploratory behaviors, so extending the period may not be ideal for studies focused on such behaviors.
Materials
Read through protocol for full details on software and programs used.
The materials used are:
-Open Field square arena (40 x 40 x 20 cm, length x width x height) housed inside a sound-attenuating chamber
-Cylinder arena: 15cm diameter x 30cm length housed inside a sound-attenuating chamber
-Video recording set up: FLIR (Point Grey Flea) camera with a CS-mount lens at a resolution of 1280 × 1024 pixels and a frame rate of 30 Hz
-Wireless motion sensor compatible with WEAR system by the Champalimaud Hardware Platform
Safety warnings
Wear appropriate PPE as required by your institution.
Ethics statement
This protocol was approved by Columbia University IACUC. Please do not perform any of these procedures unless there is prior approval from the institution's animal ethics committee.
Mice can be put into two behavioral assays.
Step case

Open-Field Test
11 steps

Sensor Habituation
Sensor Habituation
Mice are acclimated to the wireless motion sensor (~1.8 g) in their home cage for 15 minutes on the first day.
On the second day, they undergo a 30-minute acclimation period in the arena before the actual behavioral testing begins.
It is crucial to confirm that the system is functioning properly within the arena and to ensure that the sensor's battery is consistently fully charged.
Critical
Each mouse undergoes two behavioral assays over two days.
Critical
Recording Setup
Recording Setup
Behavioral recording is conducted using a FLIR (Point Grey Flea) camera with a CS-mount lens at a resolution of 1280 × 1024 pixels and a frame rate of 30 Hz. Ensure proper contrast and brightness settings to optimize animal tracking.
Open-Field Test: Mice are recorded from a top-down view for 30 minutes.
Video Acquisition and Data Analysis
Video Acquisition and Data Analysis
Videos are acquired using FlyCapture software and the open-source Bonsai visual programming environment. 
During the open-field test, mouse centroid coordinates are tracked in Bonsai, providing a rough estimation for post-hoc analysis. The recorded videos are later fully analyzed using DeepLabCut (DLC) to extract detailed activity metrics, including trajectory and velocity.
Wireless Motion Sensor Data Collection
Wireless Motion Sensor Data Collection
Motion data is collected using the WEAR system by the Champalimaud Hardware Platform. The sensor samples nine-axis motion data from a three-axis accelerometer, gyroscope, and magnetometer, with sampling rates up to 200 Hz. 
Data transmission occurs via a base station using the Harp system, accessible through software (e.g., Harp Wear) that allows for easy adjustment of sensor parameters as needed. 
The WEAR system is also compatible with Bonsai, allowing for synchronized recording between motion sensor data and video data for comprehensive behavioral analysis.