Public workspaceIsolation of Classical Monocytes from PBMCs (MB Kit No. 130-117-337)

  • Sara Lucas Del Pozo1,2,
  • Kai-Yin Chau 1,2,
  • Jane Macnaughtan1,2,
  • Giuseppe Uras1,2,
  • Roxana Mezabrovschi1,2
  • 1University College London;
  • 2Aligning Science Across Parkinson's
Icon indicating open access to content
QR code linking to this content
Protocol CitationSara Lucas Del Pozo, Kai-Yin Chau , Jane Macnaughtan, Giuseppe Uras, Roxana Mezabrovschi 2025. Isolation of Classical Monocytes from PBMCs (MB Kit No. 130-117-337). protocols.io https://dx.doi.org/10.17504/protocols.io.36wgqdpnyvk5/v1
License: This is an open access protocol distributed under the terms of the Creative Commons Attribution License,  which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Protocol status: Working
We use this protocol and it's working
Created: February 06, 2025
Last Modified: February 24, 2025
Protocol Integer ID: 119990
Keywords: ASAPCRN
Funders Acknowledgements:
Aligning Science Across Parkinson's
Grant ID: ASAP-000420
Abstract
This protocol describes the isolation of classical monocytes from peripheral blood mononuclear cells.
Guidelines
Magnetic labeling:

  • Work fast, keep cells cold, and use pre-cooled solutions. This will prevent capping of antibodies on the cell surface and non‑specific cell labelling (but PBMC may be activated by cool, so work at RT with the cells).
  • Volumes for magnetic labeling given are for up to 107 total cells (when working with fewer than 107 cells, use the same volumes as indicated. When working with higher cell numbers, scale up all reagent volumes and total volumes accordingly, e.g. for 2×107 total cells, use twice the volume of all indicated reagent volumes and total volumes).
  • For optimal performance it is important to obtain a single‑cell suspension before magnetic labeling. Pass cells through 30 μm nylon mesh (Pre-Separation Filters (30 μm), # 130-041-407) to remove cell clumps which may clog the column. Moisten filter with buffer before use (we use a 1mL siringe and 26-27G needle).
  • The recommended incubation temperature is room temperature. Higher temperatures and/or longer incubation times may lead to non‑specific cell labeling. Working on ice may require increased incubation times.
Materials
Reagent and instrument requirements:

  • Buffer: Prepare a solution containing phosphate-buffered saline (PBS), pH 7.2, 0.5% bovine serum albumin (BSA), and 2 mM EDTA by diluting MACS BSA Stock Solution (# 130-091-376) 1:20 with autoMACS® Rinsing Solution (# 130-091-222). Keep buffer cold (2−8 °C). Degas buffer before use, as air bubbles could block the column.
  • LS MACS Columns (Void volume: 400 µL. Reservoir volume: 8 mL)
  • MidiMACS Separator.
Safety warnings
The protocol needs prior approval by the users' Institutional Review Board (IRB), Institutional Animal Care and Use Committee (IACUC) or equivalent ethics committee(s) as applicable.
Before start
The protocol needs prior approval by the users' Institutional Review Board (IRB), Institutional Animal Care and Use Committee (IACUC) or equivalent ethics committee(s) as applicable.
Sample Preparation
Sample Preparation
15m
15m
When working with anticoagulated peripheral blood or buffy coat, isolate PBMCs by density gradient centrifugation.

To reduce the number of thrombocytes in starting material, it is strongly recommended to perform a thrombocyte removal step. Therefore, resuspend cells in autoMACS® Rinsing Solution (# 130-091-222) and centrifuge at Centrifigation200 x g, Room temperature, 00:15:00 . Thrombocytes will remain in supernatant while the cell pellet will be used for CD14+CD16– classical monocyte isolation. If necessary, repeat thrombocyte removal steps.

Note
The Thrombocytes Removal Reagent can be optionally used for further removal of platelets from the sample but may result in lower recovery of monocytes.

15m
Centrifigation
Dead cells may bind non-specifically to MACS MicroBeads. To remove dead cells, we recommend using density gradient centrifugation or the Dead Cell Removal Kit (# 130-090-101). (We have never done that).

Magnetic labeling protocol:
Magnetic labeling protocol:
20m
20m
Determine cell number.

Centrifuge cell suspension at Centrifigation300 x g, 00:10:00 . Aspirate supernatant completely.

10m
Centrifigation
Resuspend cell pellet in Amount30 µL of buffer per 107 total cells.

Add Amount10 µL FcR Blocking Reagent, human per 107 total cells.

Pipetting
Add Amount10 µL of Classical Monocyte Biotin-Antibody Cocktail per 107 total cells.

Pipetting
(Optional) Add Amount5 µL of Thrombocyte Removal Reagent per 107 total cells.

Pipetting
Optional
Mix well and incubate for Duration00:05:00 at TemperatureRoom temperature .

5m
Incubation
Mix
Add Amount30 µL of buffer per 107 cells.

Pipetting
Add Amount20 µL of Anti-Biotin MicroBeads per 107 cells.

Pipetting
Mix well and incubate for additional Duration00:05:00 at TemperatureRoom temperature . Proceed to magnetic separation.

5m
Incubation
Mix
Magnetic Separation
Magnetic Separation
Always wait until the column reservoir is empty before proceeding to the next step.

Place column in the magnetic field of the MidiMACS Separator.

Prepare column by rinsing with the appropriate amount of buffer: LS: Amount3 mL .

Apply cell suspension onto the column. Collect flow-through containing unlabeled cells, representing the enriched CD14+CD16– monocytes.

Wash column with Amount3 mL of buffer. Collect unlabeled cells that pass through, representing the enriched CD14+CD16– cells, and combine with the flow-through from step 15.

Note
Perform washing steps by adding buffer aliquots as soon as the column reservoir is empty.

Wash
(Optional) Remove column from the separator and place it on a suitable collection tube. Pipette Amount5 mL of buffer onto the column. Immediately flush out the magnetically labeled non-monocyte cells by firmly pushing the plunger into the column.

Pipetting
Optional
Magnetic Separation Using LS Columns
Magnetic Separation Using LS Columns
Resuspend up to 108 total cells in Amount500 µL of buffer.

When working with fresh anticoagulated blood or buffy coat, dilute before separation 1:2 with buffer. Alternatively, use the StraightFrom® Whole Blood MicroBeads or StraightFrom Buffy Coat MicroBead Kits in combination with Whole Blood Columns.

To remove clumps, pass cells through Pre-Separation Filters.

Apply cell suspension onto the prepared LS Column. Collect flow-through containing unlabeled cells.

Wash LS Column with Amount3 mL of degassed buffer. Collect unlabeled cells that pass through and combine with the flow-through from step 19.

Note
Perform washing steps by adding buffer aliquots as soon as the column reservoir is empty.

Wash
Remove LS Column from the separator and place it on a new collection tube.

Pipette Amount5 mL buffer onto the LS Column. Immediately flush out fraction with the magnetically labeled cells by firmly applying the plunger supplied with the column.

Pipetting
(Optional) To increase the purity of the magnetically labeled fraction, the eluted fraction can be enriched over a second LS Column (for up to 108 magnetically labeled cells). Repeat the magnetic separation procedure as described in steps 19 to 22 by using a new column.


Note
Macrophage Marker (CD11b, CD68, CD163, CD14, CD16) Antibody Panel - Human (ab254013)

Optional